1. Refrigerated Reagent Compartments
-
Real workstation consolidation with up to 40 different analytes in reagent pan (40 positions for for reagent1 and 40 positions for reagent2)
-
Ready to use liquid stable reagents, mainly monoreagents.
-
Liquid detection and remaining test number calculation
-
Wide test ranges (See test menu)
-
Stable cooling system by peltier element.
-
Cover for protecting reagents from evaporation
-
Continuous cooling at switching of analyzer main unit (Lamp saving system)
-
Optional ready onboard SINNOWA reagent bottles
-
Advanced automated/manual/selective/calibration and reagent quality control
2. Washing Station
-
High tech wash station to ensure a valid diagnostics (8 times washing each reaction cuvets)
-
Dirtiness control (Auto.blank control after washing react. cuvets)
-
Vacuum draining liquid and 37°C preheated distillated water cleaning system
yielding to quick easy/drying system of reaction cuvettes system. (Patented Technology)
-
Reaction cuvettes cleaning (washing) system with preheated distillated water
based on chemical cleaning function effect of 37°C heated distillated water. (Patented Technology)
-
Eight fold water cleaning followed by a separate drying step to gain optimum system performance
3. Mixing Probe (Stirrer)
-
Automated cleaning probe tips after each cleaning process
-
High precision mixer stations to ensure excellent reaction conditions (Two mixing probes)
-
Standardized mixing proced. across the whole range of analysis
-
Different mixer positions for individual reaction steps (After reagent 1 and after reagent 2)
4. Reaction cuvettes wheel
-
90 reaction cuvets
-
Non disposable plastic /quartz cuvettes (Reusable cuvettes)i
-
Software driven carry over elimination
-
Flexibility of total reaction volume between 180 µl-300 µl
-
Autocontrolled by peltier element and optimized reaction temperature at 37°C , accurate ± 0,1 °C variation
-
Rear sprectrophotometry of concave flat field grating fiber optic cable technology that provides low reaction detection at the same time on 14 different wavelengths.
-
Cover for protecting reactions from evaporation, contamination and external light effects
-
Photometric test accuracy:%1 Between 0.0000 OD(Abs.) to 5.0000 OD (Abs.)
-
Carry Over Value :( Influencing one test from another) Less than %1
5. ISE Unit
-
Integrated ISE unit.
-
High quality ISE electrodes for Na, K, Cl,(or Li), PH and Ca.
-
12 months shelf life for all electrodes
-
100 tests/hour (If ISE mode only)
6. Sample Probe
-
Sample volume as small as 2,0 µl as high as 100 µl
-
Stable probe sensing system with liquid level detection, low sample alarm with voice/warning messages
-
Probe save system (Collision protection- Crash prevention )
-
Clot detection system (Clog detection system)
-
Sample rerun and auto dilution (predilution or post dilution function)
-
Primary(Vacuum blood tube), secondary tube(cuvet) compatibility
7. Sample Pan(Table)
-
Positive sample identification to eliminate any sample mix ups
-
Barcode reading technology to define different sample materials or other sample specifics
-
60 samples on board at the time for long walk away (All locations are ready to use for control, calibrator, urgent-random access tests)
8. Reagent Probe
-
Stable probe sensing system with liquid level detection
-
Probe save system (Collision protection- Crash prevention )
-
Reagent volume as small as 10 µl-300 µl
-
Calculation of remaining tests/vial, alarm after critical preprogrammed test number4
-
Low reagent alarm with voice/warning messages
9. Windows based/integrated management program
-
Compatible with windows 2000, XP, Vista
-
User friendly interface
-
Multitasking, flexible management program
-
Automated maintenance (Combined many tasks at start up)
-
Easy able to translate local language (Ready English,French, Turkish, Chinese, Arabic, Persian, Italian versions)
-
Online status of reaction, reagent and sample plates
-
Online monitoring Absorbance-time plot
-
Profile inputting, calculated items
-
Ready application inserts for SINNOWA Biochemistry&Turbidimetry Reagents, open reagent application system
-
Online control system from central technic service (Remote Control)
-
Unlimited users&profiles, more than 300 different tests program location
-
Levey-jennings QC Charts, QC programs, QC results printing, statistical data extraction
10. Size and power requirements
-
Size (cm):65-80-70 Weight:120 Kg
-
Power: 220 Volt/50 Hz..
Thông số kỹ thuật
• Discrete constant speed 380 T/H
• Random Access (Emergency test input mode), Easy mode (Continuous loading mode),
Group loading.
• Automated HIS/LIS application (Data accept&send from/to hospital automation
system automatically)
• Test Methods: Kinetic, Endpoint, Differential(Sample Blank), Fixed Time, Protein
immunoassay,
Turbidimetric, Multicalibrators tests (1-6 Calibrator)
• 8-14 Different filters between 340nm-800nm give up compatibility all kind of tests
• External&Internal barcode reader for sample and reagents
• Low distillated water consumption(2-5 Liter/hour)
• 1 Probes(Sample-ISE and R1- R2 Probe) and Mixing Probe (1 Probe)